Cicode and page subscriptions to the same tag will result in two handles. The 32768 threshold is localised to each client where the count is incremented for each subscription. 43098 When TagSubscribe() handle is greater than 32768, a negative value representing the handle is incorrectly passed to the Cicode callback function This issue affects v7.0 Service Pack 2 display clients that use the TagSubscribe() function. To resolve, use the new drop down option(s) available in Service Pack 2 and above. trend tags, reports, events) may experience Invalid time format compile errors after upgrading to Service Pack 2. 36365.2 Invalid time format compile error after upgrading from v7.0 Service Pack 1 French and German machines that have been upgraded to v7.0 Service Pack 1 and use the Period field in any Project Editor form (e.g.
To resolve and reinstate protocols in the drop down list, reinstall their corresponding Driver Pack(s).
Table 2 - Known Issues Issue Number Issue Title and Description 36365.1 Protocols are missing from the IO Devices form after installation of a v7 service pack French and German machines may experience this issue if drivers have been installed after the original VijeoCitect install. Known Issues: This Service Pack contains the known issues described below. Day of the month format changes from “DD” to “DDter”. Days of the week change from German to English. German Day of the month format changes from “DD.” to “DDter”. Day of the month format changes from “DDeme” to “DDe”. Month names change from lower-case to title-case. Days of the week change from French to English. Table 1 - French and German Period field changes in Service Pack 2 Upgrading from v7.0 release Upgrading from v7.0 Service Pack 1 French No change. For more information see issues 36365.5.2 on the following page, and Table 1 below.
Users upgrading from Service Pack 1 may need to update their projects to match the new drop down options in Service Pack 2. This caters to the majority of French and German customers who have not yet upgraded to Service Pack 1 and would prefer not to reconfigure their projects. These changes, with the exception of German day of the month, have been reversed in Service Pack 2. Important: In v7.0 service pack 1, an attempt was made to translate all Project Editor Period field text strings for French and German installs into their localised form. Parameters which may have been customised and need to be checked are: node=unknown Server=0 Data= ANSIToOEM=0 DBFILES=80 PrintFont=Courier New PrintPoint=6 AlarmBufferSize=39 If these have been changed since the original VijeoCitect install, backup citect.ini or take note of pre-service pack settings then restore after installing the service pack. Important: During installation, some citect.ini parameters will be changed to default values. Ensure that the Incremental Compile menu option (in Project Editor→Tools→Options) is not checked, or set INCREMENTALCOMPILE=0. To force an upgrade, edit the Citect.ini file and set UPGRADE=1. Failure to do so will result in conflicting database size messages. Important: All projects must be upgraded and recompiled after installing this Service Pack. We provide complete repair service to all brands of industrial automation products including: ABB, Allen-Bradley, Cutler-Hammer, Emerson, Eurotherm, Fanuc, GE, Indramat, Siemens and many more.This document describes the modifications and fixes made in VijeoCitect version 7.0 Service Pack 2 as well as providing installation information. Questions: Please contact Customer Service at: Schneider Electric Industrial Repair Services (Canadian customers see below) Contact Us Contact Information for USA and International